{"title":"Accessories","description":"","products":[{"product_id":"thermosorb-n-airsampling-cartridges-pack-of-20","title":"ThermoSorb-N Airborne Nitrosamine Sampling Cartridges (Pack of 20) | Ellutia","description":"\u003cp\u003e \n\u003c!-- ============================================================\n     Ellutia ThermoSorb-N volume pricing table\n     Best pasted into a Shopify CUSTOM LIQUID section placed\n     just under the price \/ Add to cart block.\n     Avoid the standard rich-text description editor, as it can\n     strip the \u003cstyle\u003e block. A Custom Liquid section keeps it intact.\n     To update later, edit the prices and the end date in the text.\n     ============================================================ --\u003e\n\n\u003c\/p\u003e\u003cdiv class=\"ell-vt\"\u003e\n  \u003cp class=\"ell-vt-title\"\u003eBuy more, pay less per pack\u003c\/p\u003e\n\n  \u003cdiv class=\"ell-vt-grid\"\u003e\n\n    \u003cdiv class=\"ell-vt-card\"\u003e\n      \u003cp class=\"ell-vt-qty\"\u003e1 to 2 packs\u003c\/p\u003e\n      \u003cp class=\"ell-vt-price\"\u003e£599.99\u003c\/p\u003e\n      \u003cp class=\"ell-vt-unit\"\u003eper pack\u003c\/p\u003e\n      \u003cp class=\"ell-vt-save\"\u003eStandard price\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ell-vt-card ell-vt-card--mid\"\u003e\n      \u003cp class=\"ell-vt-qty\"\u003e3 to 9 packs\u003c\/p\u003e\n      \u003cp class=\"ell-vt-price\"\u003e£509.99\u003c\/p\u003e\n      \u003cp class=\"ell-vt-unit\"\u003eper pack\u003c\/p\u003e\n      \u003cp class=\"ell-vt-save ell-vt-save--on\"\u003eSave 15%, £90 a pack\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ell-vt-card ell-vt-card--best\"\u003e\n      \u003cspan class=\"ell-vt-ribbon\"\u003eBest value\u003c\/span\u003e\n      \u003cp class=\"ell-vt-qty\"\u003e10 or more packs\u003c\/p\u003e\n      \u003cp class=\"ell-vt-price\"\u003e£479.99\u003c\/p\u003e\n      \u003cp class=\"ell-vt-unit\"\u003eper pack\u003c\/p\u003e\n      \u003cp class=\"ell-vt-save ell-vt-save--on\"\u003eSave 20%, £120 a pack\u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003cp class=\"ell-vt-foot\"\u003e\n    Discount applied automatically at checkout, no code needed. Offer ends 30 June. Free worldwide shipping on every order.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n  .ell-vt {\n    font-family: \"PT Sans Narrow\", Arial, sans-serif;\n    max-width: 640px;\n    margin: 24px 0;\n    color: #1d2b2c;\n  }\n  .ell-vt-title {\n    font-size: 20px;\n    font-weight: 700;\n    margin: 0 0 14px;\n    color: #009ca6;\n  }\n  .ell-vt-grid {\n    display: flex;\n    gap: 12px;\n    flex-wrap: wrap;\n  }\n  .ell-vt-card {\n    flex: 1 1 160px;\n    border: 2px solid #e1e8ea;\n    border-radius: 8px;\n    padding: 16px 14px;\n    text-align: center;\n    position: relative;\n    background: #ffffff;\n  }\n  .ell-vt-card--mid { border-color: #009ca6; }\n  .ell-vt-card--best {\n    border-color: #ff7247;\n    background: #fff6f3;\n  }\n  .ell-vt-ribbon {\n    position: absolute;\n    top: -11px;\n    left: 50%;\n    transform: translateX(-50%);\n    background: #ff7247;\n    color: #ffffff;\n    font-size: 12px;\n    font-weight: 700;\n    letter-spacing: 0.04em;\n    text-transform: uppercase;\n    padding: 3px 12px;\n    border-radius: 12px;\n    white-space: nowrap;\n  }\n  .ell-vt-qty {\n    font-size: 15px;\n    font-weight: 700;\n    margin: 0 0 8px;\n  }\n  .ell-vt-price {\n    font-size: 26px;\n    font-weight: 700;\n    margin: 0;\n    line-height: 1.1;\n  }\n  .ell-vt-unit {\n    font-size: 13px;\n    color: #5a6b6c;\n    margin: 2px 0 10px;\n  }\n  .ell-vt-save {\n    font-size: 14px;\n    margin: 0;\n    color: #5a6b6c;\n  }\n  .ell-vt-save--on {\n    color: #ff7247;\n    font-weight: 700;\n  }\n  .ell-vt-foot {\n    font-size: 13px;\n    color: #5a6b6c;\n    margin: 14px 0 0;\n    line-height: 1.4;\n  }\n\n  @media (max-width: 540px) {\n    .ell-vt-grid { flex-direction: column; }\n    .ell-vt-card { flex: 1 1 auto; }\n  }\n\u003c\/style\u003e\n\u003cp\u003e\u003cspan\u003eThermoSorb-N cartridges collect airborne nitrosamines accurately, without artifact formation. Designed for personal and workplace monitoring. Pack of 20, made in the UK by Ellutia.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003e\u003cmeta charset=\"UTF-8\"\u003e✓ Designed \u0026amp; manufactured in the UK  |  ✓ Zero artifact formation \u003c\/span\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003e✓ Free worldwide shipping  |  ✓ Dispatched within 2-3 days\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"margin: 24px 0 32px 0;\"\u003e\n\u003ch2 style=\"font-size: 24px; text-transform: uppercase; letter-spacing: 0.08em; color: #4a4949; margin-bottom: 16px;\"\u003eTrusted by\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; align-items: center; gap: 16px; flex-wrap: wrap;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/Mitsubishi.png?v=1778677418\" alt=\"Mitsubishi Heavy Industries\" style=\"height: 30px; width: auto; opacity: 0.6; box-shadow: none !important; border: none !important; border-radius: 0 !important; background: none !important;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/SGS.png?v=1778677447\" alt=\"SGS\" style=\"height: 40px; width: auto; opacity: 0.6; box-shadow: none !important; border: none !important; border-radius: 0 !important; background: none !important;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/Eurofins.png?v=1778677490\" alt=\"Eurofins\" style=\"height: 100px; width: auto; opacity: 0.6; box-shadow: none !important; border: none !important; border-radius: 0 !important; background: none !important;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/IMAT.png?v=1778677515\" alt=\"IMAT Automotive\" style=\"height: 40px; width: auto; opacity: 0.6; box-shadow: none !important; border: none !important; border-radius: 0 !important; background: none !important;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eFOR ACCURATE AIRBORNE NITROSAMINE MONITORING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eAirborne nitrosamine monitoring is only useful if the results you get are accurate. Many collection methods introduce artifact formation, producing false positives from solid sorbents, or false negatives through sample loss in wet traps. Nitrosamines also degrade under UV light, creating further risk of unreliable data.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe ThermoSorb-N is built to eliminate these problems. Each cartridge contains an artifact trap with an amine-trapping agent and a nitrosation inhibitor, preventing in-situ nitrosamine formation during collection. The opaque plastic construction blocks UV degradation. Solid sorbent materials prevent sample loss over time and temperature. The result is a nitrosamine reading that accurately reflects actual airborne levels.\u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eThe ThermoSorb-N is built for:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eWorkplaces where workers may be exposed to airborne nitrosamines and personal monitoring is required\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eIndustrial environments where N-nitroso compound concentrations need to be measured and documented\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eHealth and safety teams that need reliable, reproducible data for compliance and reporting purposes\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eLabs running analysis with the \u003ca href=\"https:\/\/www.ellutia.com\/thermal-energy-analyser\" target=\"_blank\"\u003eEllutia 800 Series TEA\u003c\/a\u003e, where sample integrity from collection through to analysis matters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHow it works\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe ThermoSorb-N clips to a pocket or lapel and connects to a personal sampling pump. Air passes through the cartridge during the sampling period. The amine trap and nitrosation inhibitor prevent false readings forming during collection. Once sampling is complete, the end caps, stored on the cartridge itself so they are always to hand, are replaced, and the cartridge is sealed in its foil pouch for transport to the lab.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eAnalysis is straightforward. A solvent back-flushing technique elutes the sample, which is then run on a gas chromatograph connected to an \u003ca href=\"https:\/\/www.ellutia.com\/thermal-energy-analyser\" target=\"_blank\"\u003eEllutia 800 Series TEA\u003c\/a\u003e detector. Results are available in minutes. If you do not have a TEA in-house, Ellutia can analyse your samples for you. Contact \u003ca href=\"mailto:sales@ellutia.com\" class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\"\u003einfo@ellutia.com\u003c\/a\u003e to arrange analysis.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIf unusually high concentrations of N-nitroso compounds are expected, a second cartridge can be attached piggyback style, with no additional hardware needed.\u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat makes the ThermoSorb-N different\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhen tested against activated charcoal, alumina, Florisil, silica gel, and Tenax GC sorbents, the ThermoSorb-N was the only solid sorbent to show zero detectable nitrosamine formation across all five target compounds. It also outperformed wet trap methods, which showed sample loss over both time and temperature. The ThermoSorb-N showed no sample loss under the same conditions.\u003c\/p\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePack size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e20 cartridges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSorbent type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSolid sorbent with artifact trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eArtifact control\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAmine-trapping agent and nitrosation inhibitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUV protection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOpaque plastic construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSampling method\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePersonal sampling pump (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAnalysis method\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSolvent back-flush, GC-TEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCompatible detector\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eEllutia 800 Series TEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eStorage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSealable foil pouch included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOrigin\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDesigned and manufactured in the UK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat's included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e20 x ThermoSorb-N air sampling cartridges\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eSealable foil pouches for transport and storage\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eData log with coded labels for samplers, analysis vials, and mailing envelopes\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eEnd caps (stored on cartridge)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eFree worldwide shipping on all orders. Orders dispatched within 2-3 working days. For questions about your order, contact \u003ca class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"mailto:sales@ellutia.com\"\u003einfo@ellutia.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eNeed the complete nitrosamine monitoring system?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe ThermoSorb-N works with the \u003ca href=\"https:\/\/www.ellutia.com\/thermal-energy-analyser\" rel=\"noopener\" target=\"_blank\"\u003eEllutia 800 Series TEA detector for GC \u003c\/a\u003efor selective N-nitroso compound analysis. Visit ellutia.com to learn more about the 800 Series TEA and the complete nitrosamine testing workflow.\u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat is the ThermoSorb-N used for?\u003c\/strong\u003e The ThermoSorb-N is used to collect airborne nitrosamines for personal and workplace monitoring. It is designed for environments where workers may be exposed to N-nitroso compounds, and where accurate, reliable sampling data is required for health, safety, and compliance purposes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHow does the ThermoSorb-N prevent false results? \u003c\/strong\u003eEach cartridge contains an artifact trap incorporating an amine-trapping agent and a nitrosation inhibitor. This prevents nitrogen oxides from reacting with amines during collection, which is the main cause of false positives with other solid sorbents. The opaque plastic construction prevents UV degradation, and solid sorbent materials prevent sample loss over time and temperature.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat sampling pump do I need?\u003c\/strong\u003e The ThermoSorb-N is designed for use with personal sampling pumps. The pump is not included in this pack. Contact \u003ca class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"mailto:sales@ellutia.com\"\u003einfo@ellutia.com\u003c\/a\u003e if you need guidance on compatible pumps.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHow is the sample analysed after collection?\u003c\/strong\u003e A solvent back-flushing technique is used to elute the collected sample. It is then analysed using a gas chromatograph connected to an Ellutia 800 Series TEA detector. Analysis takes minutes and can detect volatile N-nitroso compounds at part-per-billion levels.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eAre the cartridges single use?\u003c\/strong\u003e Yes. Each ThermoSorb-N cartridge is designed for single use. A pack of 20 cartridges is supplied.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat industries use the ThermoSorb-N?\u003c\/strong\u003e The ThermoSorb-N is used across a range of industries where nitrosamine exposure is a concern, including rubber and chemical manufacturing, pharmaceuticals, food production, and any workplace where N-nitroso compounds may be present in the air.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCan a second cartridge be used for high concentration environments?\u003c\/strong\u003e Yes. Where unusually high concentrations of N-nitroso compounds are expected, a second cartridge can be attached to the sampling system in piggyback style, extending the effective sampling capacity without any additional equipment.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhere are ThermoSorb-N cartridges made? \u003c\/strong\u003eThe ThermoSorb-N is designed and manufactured in the UK by Ellutia, based in Ely, Cambridgeshire.\u003c\/p\u003e","brand":"Ellutia","offers":[{"title":"Default Title","offer_id":44087181213999,"sku":"32010001","price":599.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/Thermosorb_Lifestyle-10.jpg?v=1776779130"},{"product_id":"7000-gc-flowmeter","title":"7000 GC Flowmeter | Measure 8 Gases - Ellutia","description":"\u003ch4\u003e\u003cstrong\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003eSale ends 30 April! \u003c\/span\u003eSave £100 + FREE worldwide shipping.\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch5\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e✓ 12-month warranty | ✓ UKAS-traceable calibration  \u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003e✓ Free worldwide shipping | ✓ Dispatched within 2–3 days\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv style=\"margin:24px 0 32px 0;\"\u003e\n  \u003cp style=\"font-size:24px; text-transform:uppercase; letter-spacing:0.08em; color:#4a4949; margin-bottom:16px;\"\u003eTrusted by\u003c\/p\u003e\n  \u003cdiv style=\"display:flex; align-items:center; gap:16px; flex-wrap:wrap;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/BP.png?v=1778681056\" alt=\"BP\" style=\"height:100px; width:auto; opacity:0.6; box-shadow:none !important; border:none !important; border-radius:0 !important; background:none !important;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/PerkinElmer.png?v=1778681087\" alt=\"PerkinElmer\" style=\"height:40px; width:auto; opacity:0.6; box-shadow:none !important; border:none !important; border-radius:0 !important; background:none !important;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/SATRA.png?v=1778681175\" alt=\"SATRA\" style=\"height:40px; width:auto; opacity:0.6; box-shadow:none !important; border:none !important; border-radius:0 !important; background:none !important;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/FBI.png?v=1778681211\" alt=\"FBI\" style=\"height:40px; width:auto; opacity:0.6; box-shadow:none !important; border:none !important; border-radius:0 !important; background:none !important;\"\u003e\n  \u003c\/div\u003e\n\n\u003ch2\u003eDESIGNED FOR GAS CHROMATOGRAPHY\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eMost GC labs need to measure several different carrier gases. The 7000 does all eight,  from Helium to Hydrogen, in a single pocket-sized instrument. No adapters. No switching between devices. One calibrated unit, rechargeable, accurate to ±0.4 ml\/min.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eThe 7000 is built for labs that:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eWork with multiple carrier gases and want one tool for all of them\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eNeed a traceable calibration record for audit or compliance purposes\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eAre tired of bulky flowmeters that sit on a bench rather than travel between instruments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003cspan\u003eSpec\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 to 500 ml\/min (0.1 to 275 ml\/min for Carbon Dioxide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 ml\/min or 2.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir, Argon, Argon\/5% Methane, Carbon Dioxide, Helium, Hydrogen, Nitrogen, Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68 x 130 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnnually\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraceability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration traceable to UKAS standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEllutia 7000 GC Flowmeter\u003c\/li\u003e\n\u003cli\u003eUSB charging cable\u003c\/li\u003e\n\u003cli\u003eCalibration certificate (UKAS traceable)\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFREE worldwide shipping\u003c\/strong\u003e on all orders (limited time). Orders dispatched within 2-3 working days. 12-month manufacturer warranty included. For returns or questions, contact sales@ellutia.com.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cstrong\u003eKeep your 7000 performing year after year.\u003c\/strong\u003e\u003cspan\u003e Annual recalibration is required to maintain UKAS traceability. Add the\u003c\/span\u003e \u003ca href=\"\/products\/flowmeter-recalibration-services\"\u003eFlowmeter Recalibration Service\u003c\/a\u003e to keep your 7000 performing at its best.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 7000 work with all GC brands? - \u003c\/strong\u003e\u003cspan\u003eYes. It connects via a standard push-on adaptor and is compatible with all major GC manufacturers including Agilent, Shimadzu, PerkinElmer, and Thermo Scientific.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the 7000 need recalibrating? - \u003c\/strong\u003e\u003cspan\u003eAnnually. Ellutia's recalibration service returns a fresh UKAS-traceable certificate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need batteries? -\u003c\/strong\u003e \u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eNo. The 7000 GC Flowmeter has a built-in rechargeable battery. You charge it via USB C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it measure linear velocity as well as flow rate? \u003c\/strong\u003eYes. Select your column diameter in the options menu and the flowmeter calculates and displays linear velocity directly. You can switch between flow rate and linear velocity with a single button press.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is it made? \u003c\/strong\u003e\u003cspan\u003eThe 7000 GC Flowmeter is designed and manufactured in the UK by Ellutia, based in Ely, Cambridgeshire.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the flow range?\u003c\/strong\u003e \u003cspan\u003eThe flowmeter measures from 0.1 to 500 ml\/min for most gases, with a resolution of 0.1 ml\/min. For carbon dioxide the upper limit is 275 ml\/min.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Ellutia","offers":[{"title":"Default Title","offer_id":44816125657391,"sku":"21007000","price":799.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/GC_Flowmeter_being_used_to_measure_gas_flow.jpg?v=1776688070"},{"product_id":"ecd-wipe-test","title":"Electron Capture Detector (ECD) Wipe Test","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✓ Registered to handle Ni-63 radioactive materials | ✓ Signed report on every analysis\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✓ Laboratory analysis included | ✓ Free shipping on orders over £599.99\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eSTAY COMPLIANT. KEEP YOUR RECORDS CLEAN.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eElectron Capture Detectors contain a Nickel-63 radioactive source. Wipe testing is a legal requirement in most countries, and re-testing intervals are shorter than many labs expect. Typically, re-testing is required every one to three years, though national legislation or internal company policy may set a shorter interval.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe Ellutia ECD wipe test kit contains everything you need to take a surface sample from your detector. Return the samples to Ellutia and we handle the laboratory analysis, carried out by qualified personnel in a registered facility. You receive a detailed, signed report on every test.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eThis kit is for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eLaboratories with Electron Capture Detectors that require periodic wipe testing for regulatory compliance\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eLabs that have recently installed or received an ECD and require an initial wipe test\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eHealth and safety teams that need documented evidence of detector surface contamination status\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eAny site where a Ni-63 source is in use and wipe testing intervals are approaching or overdue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHow it works\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOrder the kit and it will be dispatched to you with everything needed to take the sample. Follow the step-by-step instructions included in the kit. Swabbing takes a matter of minutes and no specialist equipment is required. Return the collected samples to Ellutia using the details provided. We analyse the samples and send you a detailed, signed report on the outcome. If any issue is identified, we contact you immediately.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat's in the kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eSwabs and vials for sample collection\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eStep-by-step instructions for performing the wipe\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eReturn details for sending samples to Ellutia\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eLaboratory analysis by qualified personnel in a registered facility\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eA detailed, signed report on the outcome\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003eImmediate notification if contamination is detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eEach kit covers a single detector. If you have multiple ECDs on site, you will need one kit per detector.\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePart number\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e28001000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eKit covers\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSingle detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAnalysis location\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRegistered laboratory, UK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eReport\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDetailed, signed, provided on every test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRadioactive source type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNickel-63 (Ni-63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eShipping\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eStandard rates apply. Free on orders over £599.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDispatch\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eWithin 2-3 working days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eStandard shipping rates apply on this order. Free shipping is available on orders over £599.99. For questions about your order, contact \u003ca class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"mailto:info@ellutia.com\"\u003einfo@ellutia.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eNeed to dispose of an old ECD instead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIf your ECD is no longer in use, holding a Ni-63 source without the correct licence is not permitted, even temporarily. Ellutia is licensed to take ownership of and dispose of ECDs in line with UK radiation safety regulations. Visit \u003ca href=\"https:\/\/www.ellutia.com\/ecd_disposal\"\u003eellutia.com\/ecd_disposal\u003c\/a\u003e to find out more.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eHow often do I need to wipe test my ECD?\u003c\/strong\u003e In most countries, wipe testing is required at first installation and periodically thereafter. Re-testing intervals are typically every one to three years, though your national legislation or internal company policy may set a shorter interval. If you are unsure when your detector was last tested, the answer is to test it.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eDoes this kit cover multiple detectors?\u003c\/strong\u003e Each kit is designed for a single detector analysis. If you have multiple ECDs on site, you will need one kit per detector.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat is Ni-63 and why does it require testing?\u003c\/strong\u003e Nickel-63 is a low-energy radioactive isotope used as the source in Electron Capture Detectors. Because it is a regulated radioactive material, its use and maintenance are governed by radiation safety legislation. Wipe testing checks the external surface of the detector for contamination.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat happens if contamination is detected?\u003c\/strong\u003e If the analysis identifies any issue, Ellutia will contact you immediately. The signed report will detail the findings and outline the next steps.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCan I perform the wipe test myself?\u003c\/strong\u003e Yes. The kit includes step-by-step instructions and everything needed to take the sample. Swabbing takes a matter of minutes and no specialist equipment is required. Return the samples to Ellutia and we handle the laboratory analysis.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat documentation will I receive?\u003c\/strong\u003e Every analysis produces a detailed, signed report. This can be kept for your internal records and submitted to the relevant regulatory authority.\u003c\/p\u003e","brand":"Ellutia","offers":[{"title":"Default Title","offer_id":46285981122863,"sku":"28001000","price":205.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/1911\/6591\/files\/Wipe_Test_014.jpg?v=1691408731"}],"url":"https:\/\/store.ellutia.com\/collections\/accessories.oembed","provider":"Ellutia","version":"1.0","type":"link"}